Spring Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: cramtick70

H13-624_V5.5 HCIP-Storage V5.5 Questions and Answers

Questions 4

In Huawei all flash storage, the_____feature can automatically store data in different locations based on specified rules for intelligent data management.

Options:

Buy Now
Questions 5

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Buy Now
Questions 6

In OceanStor Pacific series storage systems, if a node or disk is faulty, data reconstruction in the disk pool can be automatically performed after 15 minutes.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 7

A government customer has purchased several Huawei OceanStor Dorado 18000 series storage devices for service deployment, and an engineer needs to create storage pools on the storage system. However, before doing so, the engineer must configure LUNs and LUN groups, and create the mapping between the LUN groups and host groups.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 8

An enterprise customer has purchased a Huawei OceanStor Pacific scale-out storage system for service configuration. An engineer wants to deploy the NFS file sharing service on the storage system and configure the HyperReplicatlon feature. Which of the following configuration operations are correct?

Options:

A.

When configuring HyperReplication, the engineer needs to configure the replication network route information on the primary storage system. The replication network route does not need to be configured on the secondary storage system.

B.

To use the NFSv4.0 protocol for share access, the engineer can run the "change service nfs_config nfsv40_status=enable account_name=?" command to enable the NFSv4.0 service.

C.

After a converged storage pool is created, the engineer needs to enable the file service. The HDFS or object service does not have to be enabled.

D.

When configuring HyperReplication, the engineer needs to create a remote replication pair on both the primary and secondary storage systems and then add a remote device.

Buy Now
Questions 9

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

Options:

A.

The min-queue-depth algorithm refers to the minimum queue depth algorithm. UltraPath is configured with this algorithm by default.

B.

Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

C.

The min-task algorithm is a round robin algorithm and can be used in scenarios where the service I/O models delivered by the host have little difference.

D.

The algorithms fall into three types: min-queue-depth, round-robin, and min-task.

Buy Now
Questions 10

To prevent misoperations from affecting services, a storage system controls user operation permissions and scopes based on user levels and roles. Which of the following is not a tenant management user role in the storage system?

Options:

A.

Tenant administrator

B.

Tenant protocol administrator

C.

Tenant data protection administrator

D.

Security administrator

Buy Now
Questions 11

The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.

Options:

Buy Now
Questions 12

A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?

Options:

A.

The engineer can add nodes by batch importing nodes or manually adding nodes. In either mode, authentication is not required.

B.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the management IP address of the node to be added.

C.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the service IP address of the node to be added.

D.

If the engineer selects "Batch Import Node" on DeviceManager, the engineer must fill in the downloaded template, and upload the template to complete batch import.

Buy Now
Questions 13

A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?

Options:

A.

The storage pool is faulty.

B.

In HP-UX, the application server does not have a LUN mapping whose host LUN ID is 0.

C.

In UNIX or Linux, a device node file is lost.

D.

The serial port connection parameters are incorrectly set.

Buy Now
Questions 14

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

Options:

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

Buy Now
Questions 15

Assume a scientific research Industry customer purchased several Huavvel OceanStor Pacific series scale-out storage devices for service deployment, and an engineer has configured the file service in the Distributed Parallel Client (DPC) scenario on the storage devices. To meet high performance requirements of front end services, the engineer wants to enable the CPU performance mode for the DPC node using the CU. Which of the following commands can be used to enable the CPU performance mode?

Options:

A.

cpupower frequency-info

B.

cpupower frequency-set -g performance

C.

change service ndmp_restart_servlce

D.

change pms converged_qos_policy

Buy Now
Questions 16

The_____feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.

Options:

Buy Now
Questions 17

The OceanStor Pacific series storage systems support the _______ feature. This feature uses the classic token bucket algorithm to control the traffic upper limit. If local tokens are insufficient, tokens are continuously generated and added to the token bucket based on the OPS and bandwidth upper limit of the corresponding QoS control object as the rate.

Options:

Buy Now
Questions 18

An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?

Options:

A.

SmartKit provides capabilities such as alarm reporting, file upload, and remote access.

B.

DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

C.

DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers’ O & M capabilities.

D.

The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

Buy Now
Questions 19

During routine O & M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?

Options:

A.

If the new device time is later than the deadline for saving historical performance data, the system will no longer save historical performance data.

B.

Changing the device time will affect the life spans of disks and controllers, which may trigger alarms indicating that the hardware life span expires or hardware is aging.

C.

If the new system time is later than the user-defined password expiration date, the system may force the user to change the login password.

D.

If the new device time is later than the certificate validity period, the certificate will expire.

Buy Now
Questions 20

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

Options:

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Buy Now
Questions 21

A financial customer has purchased multiple Huawei OceanProtect Backup Storage devices for service data backup protection. Which of the following statements are false about the data reduction principle of OceanProtect Backup Storage? choose all that apply

Options:

A.

The backup storage can perform deduplication and compression for LUNs but not for file systems.

B.

In the data reduction process, the system performs backup data preprocessing and then variable-length deduplication.

C.

The backup storage performs feature-based compression for different application data. After compression, the data can be directly written to disks without the need to perform any operations.

D.

In the data reduction process, backup data is divided into blocks of a fixed size based on its content for fixed-length deduplication.

Buy Now
Questions 22

In Huawei backup storage OceanProtect X3000, data reduction supports fixed-length (^duplication by default, but does not support variable-length (^duplication. Therefore, fixed-length ded11plication Is mainly used in the backup field.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 23

Huawei OceanStor Pacific series storage systems provide a recycle bin function. When a storage system deletes an old dentry. It records a write-ahead log (WAL) twice. In addition, after the dentry is deleted, the inode is also deleted.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 24

When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?

Options:

A.

Copies created using HyperCDP can be used for data analysis and application testing.

B.

When an application server sends a request to write data to the source LUN after a HyperCDP snapshot is created, the storage system uses the copy-on-write (COW) technology to save the new data to a new location in the storage pool and directs the source LUN’s pointer to the new location.

C.

HyperCDP snapshots cannot be directly mapped to hosts. To read data from a HyperCDP snapshot due to actual service requirements, the administrator needs to share the file system with the host so that the host can read the source file system data at the point in time when the HyperCDP snapshot was created.

D.

HyperCDP is a high-density snapshot and requires the system to construct file system objects. Therefore, the system memory usage is high.

Buy Now
Questions 25

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O & M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Buy Now
Questions 26

An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?

Options:

A.

Create a block storage pool.

B.

Configure the iSCSI service.

C.

Configure DPC share access on a client.

D.

Install DPC.

Buy Now
Questions 27

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

Options:

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Buy Now
Questions 28

After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?

Options:

A.

Configuring connectivity between a host and the storage system

B.

Creating a port group

C.

Creating a mapping

D.

Creating a LUN group

Buy Now
Questions 29

The backup and archiving scenario mainly involves sequential read of large I/Os, where there are more read I/Os than write I/Os and hot data areas are obvious. The service characteristics of this scenario are the same as those of the database OLAP scenario.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 30

As a next-generation storage system, Huawei OceanStor Dorado series can focus on core enterprise services and meet enterprises’ service requirements. Which of the following statements are false about Huawei OceanStor Dorado series storage systems?

Options:

A.

The back-end shared interface module of OceanStor Dorado 18000 is inserted into the enclosure. The disk enclosure connected to the interface module can be accessed by controllers in the engine at the same time.

B.

Dorado V6 series and new converged storage products use the PCIe Scale-Out architecture.

C.

OceanStor Dorado 18000 uses 200 Gbit/s RDMA shared interface modules for cross-engine expansion, implementing full interconnection between 8, 12, and 16 controllers.

D.

OceanStor Dorado 18000 supports a maximum of 28 interface modules and implements intra-engine mirroring and cross-engine interconnection through the 100 Gbit/s RDMA network.

Buy Now
Questions 31

Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

Options:

A.

During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.

B.

To view the display format of Syslog content, the engineer can run the "show notification syslog" command.

C.

To change the display format of Syslog content to CEF, the engineer can run the "change syslog-notification format_type=cef" command.

D.

If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.

Buy Now
Questions 32

Assume a financial customer purchased several Huawei scale-out storage devices for deploying the video surveillance service. This service has high requirements on performance. Therefore, the cache write policy must be set to write-through for the storage devices.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 33

During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 34

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Buy Now
Questions 35

A financial customer has purchased two Huawei flash storage devices and installed them in two equipment rooms of a local data center to deploy HyperMetro services. During quorum server network planning, only 10GE quorum links can be used when a single quorum server is deployed. 25GE and Fibre Channel networks cannot be used.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 36

Which of the following statements are false about the distributed parallel dlent (DPC) of Huawei scale-out storage products?

Options:

A.

If you want to reserve resources for deploying DPC, the available memory of compute nodes must be greater than or equal to 8 GB, and the memory reserved for the operating system must be greater than or equal to 4 GB.

B.

To enable the performance mode of CPUs, you can run the "cpupower frequency-set -g performance" command.

C.

If services running on DPC require higher performance, you can set CPUs to work in performance mode.

D.

DPC and non-uniform memory access (NUMA) are mutually exclusive. Therefore, the NUMA affinity tuning feature cannot be provided in actual scenarios.

Buy Now
Questions 37

A financial customer purchases Huawei OceanStor Pacific 9950 for service deployment. During a routine inspection, an engineer finds that a main storage disk of the device is faulty and uses SmartKit to replace it. Which of the following statements is true about replacing the disk?

Options:

A.

When removing the disk, the engineer needs to remove it from its connector, wait at least 60 seconds, and then remove the disk from the chassis.

B.

Before using SmartKit to replace the disk, the engineer needs to complete the pre-processing as prompted. After that, the engineer can continue the subsequent operations.

C.

The duration from removing the main storage disk to installing a normal one on the node cannot exceed 10 minutes. Otherwise, heat dissipation of the storage device will be affected.

D.

The interval between removing the faulty disk and inserting a normal one is at least 10 seconds. Otherwise, the disk may be damaged.

Buy Now
Exam Code: H13-624_V5.5
Exam Name: HCIP-Storage V5.5
Last Update: Apr 7, 2026
Questions: 125
H13-624_V5.5 pdf

H13-624_V5.5 PDF

$25.5  $84.99
H13-624_V5.5 Engine

H13-624_V5.5 Testing Engine

$30  $99.99
H13-624_V5.5 PDF + Engine

H13-624_V5.5 PDF + Testing Engine

$40.5  $134.99