Black Friday Madness- 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: fifty75ct

NS0-094 NetApp Hardware Support Engineer Professional Exam Questions and Answers

Questions 4

In preparation for an upgrade to ONTAP 9.6P8 software, you have uploaded the ONTAP image 96P8_q_nodar_image.tgz onto your local web server with address 192.168.10.10.

Which is correct command syntax to download this image to the cluster image repository?

Options:

A.

ClusterA:: > storage firmware download –node local –package-url

http://192.168.10.10/96P8_q_nodar_image.tgz

B.

SP ClusterA–01 > cluster image package get –url

http://192.168.10.10/96P8_q_nodar_image.tgz

C.

ClusterA:: > cluster image package get –url

http://192.168.10.10/96P8_q_nodar_image.tgz

D.

ClusterA:: > cluster image package get –url

http: //netapp.com/ontap9/downloads/96P8_q_nodar_image.tgz

Buy Now
Questions 5

Which two commands confirm whether an aggregate is WAFL inconsistent? (Choose two.)

Options:

A.

wafiron show < aggregate >

B.

node run –node < node > sysconfig –r

C.

storage aggregate show

D.

node run –node < node > sysconfig –a

Buy Now
Questions 6

Which two statements are correct when describing L1 and L2 Watch Dog Resets (WDR)? (Choose two.)

Options:

A.

L2 WDR requests creation of a core dump before reset.

B.

L1 WDR is initiated after 0.5 seconds from the event.

C.

L1 WDR performs a soft reset.

D.

L2 WDR is initiated after 2 seconds from the event.

Buy Now
Questions 7

You have replaced the cluster backend switches on a 4-node NetApp ONTAP cluster with new switches. After the replacement, you realize that the system shows errors for the old switches that were removed:

You also notice that system switch ethernet show shows four switches, the two old switches and the two new switches.

What action will resolve the issue?

Options:

A.

Perform a reboot of the affected node using the storage failover takeover command.

B.

Delete the old switches from the database using the system switch ethernet delete command.

C.

Clear the health alert using the system health alert delete command.

D.

Reconnect the old switches and download a support bundle using the system switch ethernet log collect command.

Buy Now
Questions 8

In which two sections of AutoSupport can you find information to analyze the following panic? (Choose two.)

Panic_Message: PCI Error NMI from device(s):ErrSrcID(CorrSrc(0xf00),UCorrSrc(0x18)), RPT(0,3,0):Qlogic FC 16G adapter in slot 1 on Controller

Options:

A.

HA-RASTRACE.TGZ

B.

ALL-COREDUMP.XML

C.

SSRAM-LOG

D.

PCI-HIERARCHY.XML

Buy Now
Questions 9

During a health check you observe that NetApp ONTAP software is reporting CRC errors on a network port from a node in the cluster.

Which component do you reseat?

Options:

A.

SFP

B.

cluster switch

C.

adapter

D.

data switch

Buy Now
Questions 10

When you plan an ONTAP upgrade, which NetApp tool generates a detailed upgrade plan?

Options:

A.

ONTAP System Manager

B.

Active IQ Unified Manager

C.

Upgrade Advisor

D.

Active IQ Config Avisor

Buy Now
Questions 11

On an AFF A700 system, a SAS stack is connected to SAS ports 2a and 2b. The system has an additional 4-port SAS card in slot 9.

How should the cabling the corrected for best practices?

Options:

A.

Use port 2a and 9a.

B.

Use port 2a and 9b.

C.

Use port 2a and 2c.

D.

Use port 2b and 9d.

Buy Now
Questions 12

Which two statements are true about an IOM 12 module? (Choose two.)

Options:

A.

It has two SAS ports.

B.

It has four SAS ports.

C.

It does not have an Ethernet port for alternate control path (ACP).

D.

It has an Ethernet port for alternate control path (ACP).

Buy Now
Questions 13

Which command can you use to confirm successful completion of an ONTAP upgrade?

Options:

A.

system controller sp upgrade show

B.

cluster image show-update-progress

C.

job show –jobtype upgrade

D.

system node upgrade-revert upgrade-task –node < nodename > –version < ontap Version >

Buy Now
Questions 14

You have identified that the file named quarterly_25.docx is inconsistent.

Which nodeshell command reports whether there are Snapshot copies available?

Options:

A.

“priv set advanced; file check –f quarterly_25.docx”

B.

“priv set diag; file check –v < voiname > –i < field > ”

C.

“priv set diag; snap list –f quarterly_25.docx”

D.

“priv set advanced; aggr wafliron start –f quarterly_25.docx”

Buy Now
Questions 15

You are upgrading your 6-node NetApp ONTAP cluster from ONTAP 9.9.1 to 9.16.1. As part of the ONTAP software upgrade process, you need to update the cluster switches. After you update the first switch, you receive the following AutoSupport message:

Exhibit — AutoSupport Alert

vifmgr: callhome.clus.net.degraded:alert:

Call home for CLUSTER NETWORK DEGRADED:

Large MTU Packet Loss - Ping failures detected

between Node1_clus1 (169.254.2.94) on Node1

and Node2_clus2 (169.254.248.67) on Node2.

All cluster ports and interfaces are in an up/up status.

What is causing this error?

Options:

A.

ONTAP software is not at the same version on all nodes.

B.

The RCF file has not been applied to all switches.

C.

The ONTAP software version is not compatible with some of the controllers.

D.

The cluster switches have different firmware versions.

Buy Now
Questions 16

After a panic, the customer asks you to explain the error “watchdog timeout.”

Which explanation would be appropriate?

Options:

A.

An optional software that monitors system performance.

An overloaded system fails to reset the watchdog and watchdog induces a system panic.

B.

An optional component included with Active IQ Unified Manager.

It notifies a user if watchdog fails to reach the storage system within a certain period.

C.

A service that detects and recovers from computer malfunctions.

A hardware or software error prevents update of watchdog and it induces a system panic.

D.

A service that monitors network activity and protects data.

A watchdog induces system panic to protect data if malicious activity is detected.

Buy Now
Questions 17

Users are reporting slowness when accessing certain volumes with extremely high-performance requirements via NFSv3 on a four-node switched NetApp ONTAP cluster. Other volumes on the same cluster are behaving normally. Investigation reveals that there is a high amount of throughput recorded for the cluster LIFs.

What action enables you to determine which volumes are affected?

Options:

A.

View the active CIFS sessions on the cluster to determine the affected workloads.

B.

Check the NFS file locking lease period for the affected volumes.

C.

Review NFS export policies to ensure that client subnets are listed for the affected volumes.

D.

View the NFS connected client information and review the “Remote-Reqs” counter.

Buy Now
Questions 18

A node has panicked with a PCI/NMI error. Giveback has not been performed.

Which two commands should you run to collect the logs to determine the cause? (Choose two.)

Options:

A.

pelog –a –g=2

B.

show pci –v

C.

rdfile /mroot/etc/log/SSRAM

D.

event log show

Buy Now
Questions 19

What are two valid commands that can be used to trigger an AutoSupport? (Choose two.)

Options:

A.

:: > autosupport history show-upload-details –node < nodename >

B.

:: > system node coredump upload –node < nodename >

C.

:: > autosupport invoke –node < nodename > –type all

D.

:: > autosupport invoke-core-upload –node < nodename >

Buy Now
Questions 20

Which statement best describes the functionality of RAID Error Propagation (REP)?

Options:

A.

An unrecoverable error on a user data block does not trigger a NetApp WAFL inconsistency.

B.

An unrecoverable error on a metadata block does not trigger a NetApp WAFL inconsistency.

C.

A recoverable error on a user data block triggers a NetApp WAFL inconsistency.

D.

An unrecoverable error on a user data block triggers a NetApp WAFL inconsistency.

Buy Now
Questions 21

While reviewing a fresh install of a new NetApp ONTAP HA pair, the Field Support engineer notices that the controllers do not report the same system storage configuration.

The first controller reports the following:

System Storage Configuration: Multi-Path HA

The second controller reports the following:

System Storage Configuration: Single-Path HA

There are no EMS errors, and there are no alerts on the system or on NetApp ONTAP System Manager.

What is the next step in troubleshooting this issue?

Options:

A.

Ensure that the second controller is set up for ADP.

B.

Ensure that all disk shelves are connected, with at least four SAS cables to each controller.

C.

Reboot the controller that is reporting the single-path configuration.

D.

Check cabling to the controller that is reporting the single-path configuration.

Buy Now
Questions 22

At what stage is a write acknowledged to a client?

Options:

A.

when the write is present in the local node RAM and NVRAM

B.

when the write has been flushed to disk

C.

when the write is present in the NVRAM on the local node and its HA partner

D.

when the write has been flushed from NVRAM to RAM

Buy Now
Questions 23

While setting up a replication between two clusters, an administrator receives the following error message:

Failed to create cluster peering with 'Error: RPC to peer address 192.168.31.10 failed'.

What is the cause of this issue?

Options:

A.

The cluster interconnect cables are faulty or have been disconnected.

B.

The nodes are running incompatible versions of NetApp ONTAP software.

C.

A license has expired or is invalid for one of the nodes.

D.

A firewall is blocking necessary communication ports.

Buy Now
Questions 24

Your 2-node switchless cluster controllers are being upgraded. All cables are correctly connected. After the first controller is replaced, one of the cluster LIFs is not coming online.

You examine the port by running the following command:

Exhibit — Network Port Configuration

netapp::* > network port show -port e4a|e4e

-node netapp-02 -instance

Node: netapp-02

Port IPspace Broadcast Domain Link MTU Speed(Mbps) Health

e4a Cluster Cluster down 9000 1000/- -

e4e Cluster Cluster up 9000 auto/40000 healthy

Which parameter must you change to bring e4a up?

Options:

A.

on the port, the -autonegotiate-admin field

B.

on the broadcast-domain, the -mtu field

C.

on the port, the -ignore-health-status field

D.

on the broadcast-domain, the -ipspace field

Buy Now

NAHSE |

Exam Code: NS0-094
Exam Name: NetApp Hardware Support Engineer Professional Exam
Last Update: Nov 21, 2026
Questions: 81
NS0-094 pdf

NS0-094 PDF

$22.5  $89.99
NS0-094 Engine

NS0-094 Testing Engine

$26.25  $104.99
NS0-094 PDF + Engine

NS0-094 PDF + Testing Engine

$35  $139.99