Which of the following is not a recommended display range on the Configuration Result tab page?
Quantity = 0
Quantity > 0
Quantity > 0 + Manual modification
Manual modification
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 94
“View Configuration Result On the Config Result tab page, you can obtain the detail information for the Spart, such as part number, model, list price, and quantity. Display range. Recommended value: Quantity > 0 + Manual modification. By default, the Associated Calculation function is Click here, you can enabled. If associated select the columns calculation is disabled, to be displayed. modifying configuration You can select Show does not trigger real-time subitem in the upper right part calculation, and related of Config Result to view and configuration items are not export main equipment and automatically modified export subitems of a fixed or dynamic package. You can change the configuration result based on the site requirements. Different colors indicate different”
Technical Deep Dive
A quantity of zero indicates that no usable quantity is available, so it is not a recommended display range for configuration results. Positive-quantity and manually modified results can be relevant for display.
The recommended configuration-result filter is Quantity greater than zero plus Manual modification. It lets users focus on selected items while retaining visibility into manually changed entries. Quantity equal to zero alone does not display the useful orderable result list. The page also provides associated calculation, which updates related items when enabled; disabling it requires extra manual verification.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 94.
Which of the following methods does SCT provide for transferring quotations?
Select All that Apply.
Submitting quotations
Exporting quotations
Sharing quotations
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 98
“Export a Quotation Step 1:Select the quotation, then click Export. Step 3:Set the quotation format and export information. You can export quotations in multiple formats at a time. Quotation format Quotation validity period, 3 months by default Output style of products and services. try each style to see the differences. Step 2:Check the BOQ. Error: If there are any errors, correct them before submitting the BOQ. Warning: The warning information does not affect BOQ export. You are advised to read each alarm carefully. Compared with the normal BOQs, the customized BOQs do not contain discount, formula, and hidden rows or columns. These configuration items are not used in DCF quotations. Language 29”
Technical Deep Dive
SCT supports quotation submission, quotation export, and quotation sharing. Submission routes a quotation into its review process, export produces a transferable quotation output, and sharing makes a quotation available to other recipients.
Export produces a quotation document, Share allows another authorized user to review or collaborate, and Submit starts the downstream business process. These are separate operations with different access and validation consequences. Errors must be corrected before normal submission or export, while warnings should be reviewed but need not always block processing. Sharing does not by itself create a formal transaction or approval.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 98.
For how long can the FusionDC1000A prefabricated integrated data center endure the C4 corrosion-resistance durability test?
720
1440
480
1660
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 60
“25-Year Lifespan and Corrosion/Dust/Water-Proof Design 25-year Lifespan Standard IP55 Pre-fab. Module Spraying Process Requirements UL1440h slat spray test IP5X dustproof test IPX5 waterproof test Notes:According to ISO12944, if the sample pass the salt spray test of 1440h, its estimated life can reach 25 years. 60”
Technical Deep Dive
The FusionDC1000A prefabricated module’s standard coating passes a 1440-hour salt-spray corrosion test and is rated for protection in C4 environments.
The stated 1440-hour salt-spray test relates to the enclosure coating's resistance to corrosive atmospheres, including specified C4 exposure scenarios. It is a qualification test, not the actual number of service hours before failure. Huawei links the tested coating to a projected 25-year module life under design assumptions. Actual corrosion durability depends on installation environment, maintenance, coating integrity and physical damage.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 60.
Which features are included in the cooling system of the FusionDC1000A-40ft-IT?
Select All that Apply.
Wet film humidification
Row-level cooling
"0" Condensation Risk
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 58
“FusionDC1000A-40ft solution for IT Scenario 100% Prefabrication,Plug & Play Rack Power Cooling Fire protection Management 6/8*42U IT racks 2N & N+X available Air-cooled in-row Fire protection ECC800-pro (standard) 6-9kW / rack Modular UPS Hot aisle containment FK5112(standard) NetEco 6000 (Optional) Total IT power≤54kW 12192mm×2438mm×2896mm Integrated Modular UPS In-row smart cooing Power Distribution + UPS save 1 UPS system efficiency up to 96% Wet-film Humidifier Save Energy “0” Condensation Risk@Low Load cabinet by 95% 58”
Technical Deep Dive
FusionDC1000A-40ft-IT uses in-row DX cooling. Its smart cooling system supports wet-film humidification and maintains dehumidification at low load to prevent condensation risk.
The 40-foot IT solution uses in-row air cooling with hot-aisle containment, wet-film humidification and low-load condensation-prevention controls. Wet-film evaporation can consume substantially less electricity than electrically heated steam humidification. Keeping exhaust air apart from intake air makes cooling operation more predictable. The zero-condensation phrase is Huawei's product-design claim under specified conditions; surface temperature, humidity and the dew point remain relevant physical constraints.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 58.
Which advantages do modular data centers have over traditional data centers?
Select All that Apply.
Flexible Expansion
High power density
Energy saving
Rapid Deployment
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 8
“Standard interfaces and modular ⚫ The modular construction mode architecture; Components, ⚫ Modular construction mode enables ⚫ Factory prefabrication and pre- supports high-density cloud subsystems, and IDCs are flexible planning on infrastructure test lower down the risk; On-site computing deployment, improves modularized, which facilitates rapid based on service requirements. capacity expansion meets infrastructure utilization, reduces deployment and mass production. predictable service requirements. energy consumption, and improves ⚫ Phased deployment avoids one-time overall data center usability. ⚫ The construction period is investment and construction, and shortened by more than 50% ⚫ Infrastructure effectively supports improves ROI. rapid expansion of IT services. compared with traditional mode. The modular data center adopts the modular design to achieve fast construction, on-demand deployment, high efficiency and low ”
Technical Deep Dive
Modular data centers provide scalable, add-on capacity, are prefabricated and tested for faster deployment, can accommodate high-density equipment through integrated infrastructure, and improve energy efficiency through optimized power and cooling designs.
Modular construction combines repeatable factory integration with phased scaling. Additional cabinet or infrastructure modules can be introduced as demand rises, reducing the need to build final capacity on day one. Compact distribution and targeted cooling help support higher rack densities and lower facility overheads. Prefabrication and pretesting reduce some onsite work, but site preparation, commissioning and regulatory compliance remain necessary for actual deployment.
Huawei's modular data center design emphasizes reliable power, controlled cooling, infrastructure monitoring and standardized deployment. The stated feature must be interpreted in its correct solution and configuration context. A compliant presales design combines equipment capacity, availability objectives, environmental conditions, physical installation requirements and the customer's operating needs.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 8.
Configuration quotation is an essential part of project development.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 73
“The configurator is one of the marketing tools that developed in the basic function of product configuration. The configurator can be understood as a complex vending machine. The Spart (Sales Part) is the customer-oriented sales unit of Huawei products. It is the core of product configuration. Spart Quotation Parameters The Meta CPQ is a swift, smart, and simple online configurator developed by Huawei. It makes configuration and quotation easier. 4”
Technical Deep Dive
Configuration quotation is a key project-development activity because it translates the proposed configuration into a defined scope and price, supporting planning, approval, and delivery.
Configuration and quotation translate customer requirements into compatible, priced and traceable sales parts. A technically sound concept is not ready for procurement until required equipment, accessories, services and commercial terms are represented accurately. Meta CPQ provides rule-guided model selection, price settings, validation and export or submission. This makes quotation preparation a key stage of project development rather than only an administrative formality.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 73.
The FusionModule500 cabinet measures 600 × 1100 × 2000 mm. Its rack-mounted cooling unit has a 3.5 kW cooling capacity and uses R410A refrigerant.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 52
“FusionModule500: Integrated A/C, plug and play Product Components Specifications Door spring Monitoring Unit Solution introduction: PDU • Power:220/230/240V, 50/60Hz, 1Ph+N+PE Screen Or 208V(Latin America), 60Hz, 2Ph+PE UPS • UPS: 6 kVA rack-mounted UPS IT space • Cooling system: 3.5kW integrated cooling Electronic lock • Cabinet type: cold and hot aisle containment Glass door • Dimensions = 2000 mm x 1100 mm x 600 mm Battery pack • ICT available space: ≤ 27 U (without Battery) Cooling unit 52”
Technical Deep Dive
FusionModule500 specifications list a 600 × 1100 × 2000 mm cabinet, while its rack-mounted direct-expansion cooling unit is rated at 3.5 kW and uses R410A refrigerant.
The integrated FusionModule500 cabinet measures 600 mm wide, 1100 mm deep and 2000 mm high. Its built-in direct-expansion cooling system is rated for 3.5 kW and uses R410A refrigerant in the specified product version. The 3.5 kW cooling figure does not mean the permitted integrated-cooling IT load is 3.5 kW; the referenced model is limited to 3 kW of IT equipment power.
The FusionModule500 family contains cooled and noncooled configurations with different IT power limits. The selected UPS, room cooling conditions, battery runtime and enclosure arrangement must be checked together. A rating for a particular BC configuration must not be presented as the maximum or standard feature of every FusionModule500 installation.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 52.
The air conditioners in the FusionDC1000A-40ft-IT solution use a wet-film humidifier instead of a traditional humidifier, thereby reducing power consumption.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 58
“FusionDC1000A-40ft solution for IT Scenario 100% Prefabrication,Plug & Play Rack Power Cooling Fire protection Management 6/8*42U IT racks 2N & N+X available Air-cooled in-row Fire protection ECC800-pro (standard) 6-9kW / rack Modular UPS Hot aisle containment FK5112(standard) NetEco 6000 (Optional) Total IT power≤54kW 12192mm×2438mm×2896mm Integrated Modular UPS In-row smart cooing Power Distribution + UPS save 1 UPS system efficiency up to 96% Wet-film Humidifier Save Energy “0” Condensation Risk@Low Load cabinet by 95% 58”
Technical Deep Dive
The FusionDC1000A smart cooling equipment includes a wet-film humidifier. Wet-film humidification uses evaporative humidification rather than the high electrical energy required by traditional electrode or steam humidifiers, reducing humidification power consumption.
The solution uses wet-film humidification rather than principally generating steam by electrically heating water. Evaporation from a wetted medium can substantially reduce humidification energy. Huawei's marketing comparison identifies savings of up to 95 percent under its comparison assumptions. Actual savings depend on setpoints, climate and operation. The benefit works alongside in-row precision cooling and aisle containment, not as a substitute for environmental control.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 58.
BATCH 4 • QUESTIONS 46–60
FusionModule800 offers different typical configurations based on customer load and redundancy requirements.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 40
“Converged cabinet configuration: flexible for batch production(For standard 380V scenarios) BC1L BC2L BC3L BC4L BC5L UPS 10K*1 10K*2 10K*3 20K*2 20K*3 Configurations 0~10KW(1+1) 10~20KW(N+1) 10~18KW(1+1) 30~36KW(N+1) Power Density 0~10KW 10~20kW 20~25kW 18~30kW 36~40kW 24U 40”
Technical Deep Dive
FusionModule800 has several basic configurations sized for different IT-load ranges and incorporating different redundancy designs, such as non-redundant, N+1, and 2N power arrangements.
BC1L through BC5L represent five standard 380 V FusionModule800 configurations using differing numbers of 10 kVA or 20 kVA UPS units. This allows selection according to IT load, redundancy and available space. Capacity selection cannot consider only UPS kVA: cooling output, environmental conditions, expansion and backup supply also need validation. Standardized configurations improve repeatability during presales and factory integration.
FusionModule800 uses standardized configurations for different power and availability needs. Engineers must distinguish UPS apparent-power rating, permitted IT load, cooling output, power-path redundancy and installed optional functions. Validating these parameters together prevents an apparently attractive cabinet combination from failing installation, thermal management or service-continuity requirements.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 40.
FusionModule800 is a modular data center solution built for small data centers and branch sites. It fully meets the application requirements of these scenarios.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 39
“FusionModule800: One Row One DC ⚫ Total IT racks: 0~12 rack Integrated architecture Electrical cable tray (optional) ⚫ Cooling: Rack A/C(12.5kW/pcs) Data cable tray(optional) ⚫ Cold and hot aisle containment: Cold aisle containment Spring to open the door(rear) 250mm+1100mm hot aisle containment. Camera (optional) Spring to open the door(front) ⚫ Maximum IT load: ≤ 40kW(T1), Indicator light ⚫ Power density per rack ≤ 7kW(T1) Glass PDU door 2000 mm Touch screen UPS Aisle Monitoring module Cooling 1100 mm Hot aisle 250 mm Cold aisle Maximum racks configuration: 1 ≤ N ≤ 12 39 ”
Technical Deep Dive
FusionModule800 is designed as a modular data-center solution for small data centers and branch sites.
FusionModule800 is built for smaller site deployments requiring an integrated UPS, cooling, monitoring and IT cabinet architecture. It supports up to twelve IT racks and forty kilowatts under the specified operating limits. One Row One DC simplifies construction and allows remote infrastructure management. The phrase fully meets is promotional: suitability still depends on required availability, local temperature, electricity supply, density and applicable site standards.
FusionModule800 uses standardized configurations for different power and availability needs. Engineers must distinguish UPS apparent-power rating, permitted IT load, cooling output, power-path redundancy and installed optional functions. Validating these parameters together prevents an apparently attractive cabinet combination from failing installation, thermal management or service-continuity requirements.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 39.
A configuration model can be added from Favorites to any BOQ.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 92
“Add Products to the Quotation You can add products, spare parts, or factory inspection models to a quotation. 1. On the Configure page, click Add Product. 2. Click Product. 3. Select product scope: Data Center Facility. Tips: If you know the product name, you can search for the product directly here. For example, enter the keyword UPS5000. 4. Select the required products. 5. Click Add. 23”
Technical Deep Dive
A saved configuration model in Favorites can be added to any bill of quantities (BOQ).
Favorites can speed up repetitive proposals by reusing a previously saved product configuration instead of configuring every model from the beginning. Reuse does not excuse validation of destination-country availability, sales-part lifecycle, quotation type or product compatibility. The phrase any BOQ is too absolute: the uploaded training establishes product addition workflows, but does not explicitly confirm that Favorites bypasses every restriction. Treat the option as an intended functionality statement with that limitation.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Technical verification warning: Unrestricted Favorites-to-any-BOQ functionality is not independently established by the cited slide.
Source reference: uploaded Huawei training material, PDF page 92.
Which of the following BOQ types may be used to place orders for demo products in SCT?
Demo BOQ
Promotional BOQ
Normal BOQ
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 91
“After a BOQ is created, you can set the basic information about the BOQ, such as the Quotation Name, BOQ Type, Local Office and Remarks. Parameter Description The quotation number is automatically generated by Meta CPQ. Quotation Number The quotation number will be used to submit SPQ, draft/contract, etc. Do not manually update the quotation number if it is unnecessary. The default name of a new quotation is: Quotation + Year + Month + Day + Serial Number. Quotation Name It is recommended that the quotation name be changed to the quotation name agreed by the project team in time. Normal BOQ: Only products in the saleable list can be added to a normal quotation. BOQ Type Demo”
Technical Deep Dive
In SCT, demo products are ordered using a Demo BOQ. Demo BOQs are specifically intended for demo-product configuration and use preset demo commercial settings.
A Demo BOQ draws from the approved saleable prototype list and is appropriate for demonstration equipment. A Normal BOQ is constrained to the ordinary saleable product list. Choosing the wrong quotation type can make a required item unavailable or cause validation failure. Demo transactions may use different commercial settings and should be managed separately from normal customer production orders.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 91.
What does the safety color yellow indicate?
Danger
Do Not
Actions That Must Be Carried Out
Follow Me
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 159
“Safety Colors and Signs — Understand the Meanings Before Site Visits Safety colors and signs are the Red Yellow Blue Green most basic elements at work sites. Colors and shapes together Actions that Must convey specific meanings. Dot Not Danger Be Carried Out Follow Me Safety colors, including red, Red yellow, blue, and green, convey Transfer "Do Not" and Yellow Blue Green "Stop" commands and Transfer warnings of the safety-related meanings. danger or information Transfer actions that Transfer safety-related nearby dangers. information. must be carried out. about fire Safety signs are composed of extinguishers. safety colors, geometric shapes, and symbols. There are four Mandatory Prohibition Warning Information categories of safety signs: Action prohibition, warning, mandatory”
Technical Deep Dive
Yellow is used for warning signs to indicate a hazard or dangerous condition requiring caution. This corresponds to danger rather than a prohibition, a mandatory action, or directional guidance.
Yellow indicates caution and nearby danger, most commonly used for warning signs. Red usually denotes prohibition or stop, blue indicates mandatory behavior and green is associated with safe conditions or emergency information. Color must be read together with geometric shape and pictogram. On a data-center site, yellow warning signs may identify electrical hazards, moving machinery, suspended loads or potentially hot surfaces.
The control is relevant to data center delivery sites containing electrical distribution, UPS batteries, cooling equipment and construction activities. Effective implementation combines assigned safety responsibilities, site risk assessment, applicable technical controls, personnel competence and incident reporting. Required protective measures must be selected for the actual hazard and comply with relevant local legal and engineering requirements.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 159.
The FusionDC1000A-40ft-IT solution can be used in an environment of −40°C to +55°C.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 57
“Environment FusionDC1000A-40ft Appearance corrosion Class A/B/C environment (Class C is not supported at -40 ~ -20 ℃ ) requirements Cool type Row-level air cooling Anti-seismic GR-63-CORE Zone 3(the modular structure) Anti-wind Beaufort scale 12 (Wind speed ≤ 130km/h) Atmospheric Meets the 1440-hour salt spray test requirements corrositivity Module lifespan 25 years Module dimension 12192 × 2438 × 2896 (D × W × H, mm) FusionDC1000A-40ft Site Note: The basic concept of A/B/C environment is defined by GB/T15957 and Huawei enterprise standards. The corresponding ISO9223/12944 environments are classified into C1, (C2, C3), and C4. 57”
Technical Deep Dive
FusionDC1000A-40ft-IT operating specifications list either −40°C to +45°C or −20°C to +55°C, depending on configuration, with power derating typically above +45°C. Therefore, −40°C to +55°C is not a supported single operating range.
Neither environmental configuration spans minus 40 through plus 55 degrees Celsius. The designated low-temperature range extends to plus 45 degrees, while the high-temperature range begins at minus 20 degrees. Combining the low end of one envelope with the high end of another produces an unsupported claim. Cooling behavior, outdoor condenser performance and possible power derating make these limits important at presales design time.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 57.
Which functions can the local smart screen of the micro-module provide?
Select All that Apply.
Facial recognition login for the surveillance system
Core subsystem information display
PUE demonstration
Facial recognition access control
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 47
“Smart O & M: facial recognition for login and doors opening Liveness detection, Reliable effectively preventing video or photo unlock Facial recognition: • Logging in to the Management System through facial recognition in the local PAD • Opening the cabinet door Key data comparison: Accurate identification Fast recognition and wide range Efficient after wearing glasses, • Recognition time < 1s identification time < • Maximum identification distance: 3 m 1s • Accuracy >99.6% Facial data and operation recording • Supports facial data management of a Security algorithm, maximum of 16 authorized persons. Accurate facial recognition Traditional mode: mechanical key: • Operation data can be recorded to ensure accuracy > 99.6% Poor convenience security. 47”
Technical Deep Dive
The local smart screen provides visibility into core subsystem information and can display PUE. It also supports facial-recognition-based, keyless door opening, which is an access-control function. Facial recognition for local application login does not establish facial-recognition login for a surveillance system.
The local PAD displays subsystem information and supports operational functions such as a module PUE view. On appropriately equipped systems, facial recognition can authorize door opening. The training explicitly describes facial recognition for login to the local management application, not to the video surveillance system. These distinct login targets explain why the surveillance-system option is not supported by the cited wording.
Huawei's modular data center design emphasizes reliable power, controlled cooling, infrastructure monitoring and standardized deployment. The stated feature must be interpreted in its correct solution and configuration context. A compliant presales design combines equipment capacity, availability objectives, environmental conditions, physical installation requirements and the customer's operating needs.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 47.
What cooling mode is supported by FusionModule800?
Water-cooling
Air-cooling
Liquid-cooling
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 39
“FusionModule800: One Row One DC ⚫ Total IT racks: 0~12 rack Integrated architecture Electrical cable tray (optional) ⚫ Cooling: Rack A/C(12.5kW/pcs) Data cable tray(optional) ⚫ Cold and hot aisle containment: Cold aisle containment Spring to open the door(rear) 250mm+1100mm hot aisle containment. Camera (optional) Spring to open the door(front) ⚫ Maximum IT load: ≤ 40kW(T1), Indicator light ⚫ Power density per rack ≤ 7kW(T1) Glass PDU door 2000 mm Touch screen UPS Aisle Monitoring module Cooling 1100 mm Hot aisle 250 mm Cold aisle Maximum racks configuration: 1 ≤ N ≤ 12 39 ”
Technical Deep Dive
FusionModule800 uses a direct-expansion, air-cooled cooling system. Therefore, its supported cooling mode is air-cooling.
FusionModule800 uses rack-mounted air-cooled direct-expansion equipment. A refrigerant loop removes server heat and rejects it to the outdoor environment, while fans and containment manage airflow through the IT cabinets. The solution is not presented as a chilled-water or direct-to-chip liquid-cooling platform in the cited product configuration. Installed capacity and redundancy must satisfy the actual heat load.
FusionModule800 uses standardized configurations for different power and availability needs. Engineers must distinguish UPS apparent-power rating, permitted IT load, cooling output, power-path redundancy and installed optional functions. Validating these parameters together prevents an apparently attractive cabinet combination from failing installation, thermal management or service-continuity requirements.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 39.
Safety signs consist of safety colors, geometric shapes, and symbols. Which types of safety signs are there?
Select All that Apply.
Prohibition sign
Information
Mandatory action
Warning sign
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 159
“Safety signs are composed of extinguishers. safety colors, geometric shapes, and symbols. There are four Mandatory Prohibition Warning Information categories of safety signs: Action prohibition, warning, mandatory action, and information. * Reference standard: GB 2894-2008 Safety Signs and Guidelines for the Use * Reference Standard: ISO 7010 Graphical symbols - Safety colors and safety signs- Safety signs used in workplaces and public areas 22”
Technical Deep Dive
Safety-sign systems use distinct categories to communicate prohibited actions, required actions, hazards, and safety information. Prohibition signs indicate actions that must not be taken; mandatory-action signs specify required behavior; warning signs identify hazards; and information signs convey safety-related information. ISO 3864-1 establishes the colour and design principles for safety signs, and the U.S. government reference identifies these four categories in the ISO/EEC classification.
Safety sign categories are prohibition, information, mandatory action and warning. Their meanings are communicated by standardized combinations of color, shape and pictogram. Red often denotes prohibited actions, blue marks mandatory instructions, yellow marks hazards, and green denotes emergency or safe-condition information. All four classes are relevant to electrical and construction environments.
The control is relevant to data center delivery sites containing electrical distribution, UPS batteries, cooling equipment and construction activities. Effective implementation combines assigned safety responsibilities, site risk assessment, applicable technical controls, personnel competence and incident reporting. Required protective measures must be selected for the actual hazard and comply with relevant local legal and engineering requirements.
Source reference: uploaded Huawei training material, PDF page 159.
In FusionModule2000, what benefits do intelligent busbars provide compared with conventional end-of-suite solutions?
Select All that Apply.
Supports flexible expansion
Increase available cabinet space
Low power distribution loss
Easy to install
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 32
“FusionModule2000 System Overview—Power System In row UPS inside UPS+Integrated PDC, Maximum 180kW for one module Maximum 145kW for one module UPS+ precision PDC UPS+ Smart Busbar, Maximum 235kW for Maximum 310kW for one one module module 32”
Technical Deep Dive
FusionModule2000 smart busways provide modular, tap-off power distribution that supports on-demand expansion and simpler installation. Replacing end-of-suite distribution equipment frees cabinet space, and the integrated distribution path reduces power-distribution loss. Huawei documents smart busway as a FusionModule2000 power-distribution option and describes the platform’s modular design as supporting on-demand deployment and flexible expansion.
Busbar distribution facilitates modular tap-off connections and later expansion without requiring a new end-of-row distribution cabinet for every change. Moving distribution away from some rack footprints can release usable space. A properly designed busbar can also reduce connection complexity and resistive losses, although losses depend on conductor cross-section, current and installation quality. Factory-made sections simplify installation when electrical loading, earthing and protection coordination are correct.
FusionModule2000 combines electrical distribution, precision cooling and infrastructure monitoring in a scalable module design. Equipment selection must consider the actual load, local power availability, cooling redundancy, cabinet space and controller integration. Product-family capabilities can depend on whether the design uses an integrated UPS, external UPS, distribution cabinet or intelligent busbar.
Source reference: uploaded Huawei training material, PDF page 32.
FusionDC1000A-40ft includes ASD early smoke detection as a standard feature.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 58
“Fire protection Management 6/8*42U IT racks 2N & N+X available Air-cooled in-row Fire protection ECC800-pro (standard) 6-9kW / rack Modular UPS Hot aisle containment FK5112(standard) NetEco 6000 (Optional) Total IT power≤54kW 12192mm×2438mm×2896mm Integrated Modular UPS In-row smart cooing Power Distribution + UPS save 1 UPS system efficiency up to 96% Wet-film Humidifier Save Energy “0” Condensation Risk@Low Load cabinet by 95% 58”
Technical Deep Dive
For FusionDC1000A-40ft configurations, ASD very-early smoke detection is an optional or customized feature, not a standard inclusion.
Aspirating Smoke Detection continuously samples air for very early indications of combustion. Although this capability can improve fire-warning sensitivity, the installation documentation treats the ASD equipment as optional. The base FusionDC1000A product has an integrated fire protection architecture, but optional early smoke detection should not be advertised as a standard inclusion. The customer's fire strategy must verify detection, alarm and agent discharge integration.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 58.
In the FusionDC1000A-40ft-IT solution, cold and hot aisles are present between cabinets in the equipment area of the prefabricated module. The sliding door seals an aisle, creating hot-aisle containment.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 58
“FusionDC1000A-40ft solution for IT Scenario 100% Prefabrication,Plug & Play Rack Power Cooling Fire protection Management 6/8*42U IT racks 2N & N+X available Air-cooled in-row Fire protection ECC800-pro (standard) 6-9kW / rack Modular UPS Hot aisle containment FK5112(standard) NetEco 6000 (Optional) Total IT power≤54kW 12192mm×2438mm×2896mm Integrated Modular UPS In-row smart cooing Power Distribution + UPS save 1 UPS system efficiency up to 96% Wet-film Humidifier Save Energy “0” Condensation Risk@Low Load cabinet by 95% 58”
Technical Deep Dive
FusionDC1000A-40ft-IT uses hot-aisle containment: sliding doors seal the aisle to isolate hot exhaust air from the cold-air path.
The 40-foot solution uses in-row cooling and hot-aisle containment. Sliding glass doors seal relevant aisle openings to reduce mixing of hot server exhaust air with cold supply air. Containment improves temperature stability and can reduce unnecessary cooling energy use. Doors and penetrations must remain correctly sealed, and fire protection or emergency access requirements can override normal operation in specific circumstances.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 58.
If you are unfamiliar with Huawei products and the quotation process, you are advised to create a quotation through the shopping cart.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 102
“Scenario 1: create a quotation by the shopping cart Suggestions for Scenarios Scenario 1: 1. Personnel unfamiliar with Huawei products and quotation process 2. Search for products and services, add them to the shopping cart, and create a Browse & find Add products to Create Configure products, Export, share, quotation. With the e-commerce shopping products shopping cart quotations services, and commerce submit quotations experience, first-time users can get started quickly. Scenario 2: create a quotation directly Scenario 2: 1. Personnel familiar with Huawei products and quotations 2. Quickly create a quotation and go to the quotation topic. Create Search & find Configure products, Export, share, 3. The quotation process is simple and fast. quotations products services, and commerce”
Technical Deep Dive
Huawei’s quotation workflow recommends creating quotations from the shopping cart for users who are unfamiliar with Huawei products and the quotation process, because its product-browsing and cart-based flow is designed to help first-time users get started.
The shopping-cart quotation path is recommended for staff who do not yet know the product catalog or quotation process. It allows browsing, choosing products and creating the BOQ from the cart selection. Direct creation of an empty BOQ is more appropriate for experienced presales personnel who know the relevant models. Regardless of the starting method, the finished quotation must be configured, priced, validated and submitted or exported using the normal workflow.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Source reference: uploaded Huawei training material, PDF page 102.
When using the SCT configurator for the first time, first apply for an account and the required permission.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 80
“An employee needs to be associated with a distributor (company) before applying for the Meta CPQ configuration quotation permissions from the distributor. Log in to the registered Huawei account and click Associate yourself with a company at https://digitalpower.huawei.com/partner/#/en/workspace. The procedure is as follows. Step 1: Click Associate yourself with a company. Step 2: Complete the work contact information. Step 3: Enter the company/organization information and click Search. Step 4: Select the corresponding company. Step 5: Click Next. Note: If Associate yourself with a company is not displayed, you can go to My Huawei > Personal Profiles > Manage My Privilege to access the association page. 11”
Technical Deep Dive
First-time use of the SCT configurator requires an account and the appropriate access permission before it can be used.
Huawei requires new users to register or activate an account and obtain permissions before accessing protected SCT or Meta CPQ configuration functions. For partners, the account must also be associated with the appropriate company. This enables controlled access to commercial records and prevents an authenticated but unauthorized user from carrying out quotation operations. An administrator can approve or reject the necessary organizational association.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 80.
After a BOQ is created, you can promptly set its basic information, such as the BOQ name, BOQ type, office, and remarks.
True
False
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 91
“After a BOQ is created, you can set the basic information about the BOQ, such as the Quotation Name, BOQ Type, Local Office and Remarks. Parameter Description The quotation number is automatically generated by Meta CPQ. Quotation Number The quotation number will be used to submit SPQ, draft/contract, etc. Do not manually update the quotation number if it is unnecessary. The default name of a new quotation is: Quotation + Year + Month + Day + Serial Number. Quotation Name It is recommended that the quotation name be changed to the quotation name agreed by the project team in time. Normal BOQ: Only products in the saleable list can be added to a normal quotation. BOQ Type Demo”
Technical Deep Dive
A BOQ’s basic administrative details—such as its name, type, office, and remarks—can be configured after the BOQ is created.
Once a BOQ has been created, the user can edit its name, type, local office and remarks. Meta CPQ automatically assigns a quotation number that supports transaction traceability. Normal and demo quotation types have different eligible product lists. Remarks may be shared with another quotation user but are not transferred automatically into every transaction system. Maintaining these fields reduces misidentification of customer or project versions.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 91.
BATCH 7 • QUESTIONS 91–105
Which of the following is not a key activity of the SQA role as a “continuous improvement pusher”?
Establish an incentive mechanism for continuous improvement, and regularly summarize and commend continuous improvement work.
Focus on the safety and quality results of product delivery and O & M, be target-oriented, and carry out safety and quality planning. Ensure that no safety accident and quality accident occur.
Establish and implement the continuous improvement mechanism, instruct service personnel to apply scientific safety and quality engineering methods for analyzing problems and making improvement.
Regularly organize efforts to identify safety and quality improvement points and drive the continuous improvement of business.
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 118
“continuous improvement mechanism, instruct service personnel to apply scientific safety and quality engineering methods for the analysis and improvement of problems. Continuous 2. Regularly organize efforts to identify safety and quality improvement points and drive the continuous improvement of business. improvement pusher 3. Establish an incentive mechanism for continuous improvement, and regularly summarize and commend continuous improvement work. 14”
Technical Deep Dive
A continuous improvement pusher establishes and operates improvement mechanisms, promotes analytical improvement methods, identifies improvement opportunities, and motivates ongoing improvement. Focusing on delivery and O & M safety and quality outcomes, safety and quality planning, and preventing accidents is the responsibility of a safety and quality result guardian.
The Continuous Improvement Pusher establishes improvement mechanisms, identifies recurring deficiencies, encourages structured analytical methods and recognizes contributions. A target-oriented focus on delivery safety results, accident prevention and operational outcome management belongs specifically to the Safety and Quality Result Guardian. The two roles complement one another but are explicitly separated in the Huawei LBPGP activity table.
Huawei's partner quality approach distinguishes defined responsibilities from measurable outcomes and continuous improvement. Practical application requires evidence-based review, closed-loop issue handling, coordinated ownership between business departments and prevention of defective deliverables moving downstream. Training terminology should be preserved, because seemingly similar SQA roles are assigned different activities.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 118.
The FusionDC1000A solution uses a __________ height module.
5.2m
2.9m
3.6m
4.15m
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 57
“Module dimension 12192×2438×2896 (D×W×H, mm) FusionDC1000A-40ft Site Note: The basic concept of A/B/C environment is defined by GB/T15957 and Huawei enterprise standards. The corresponding ISO9223/12944 environments are classified into C1, (C2, C3), and C4. 57”
Technical Deep Dive
The FusionDC1000A prefabricated module has a specified height of 2,896 mm, equivalent to approximately 2.9 m.
The prefabricated 40-foot module has external dimensions of 12,192 by 2,438 by 2,896 millimetres. A height of 2,896 mm is approximately 2.9 m. Site engineers must consider not just the enclosure size but also access roads, lifting clearance, foundation and cooling equipment service zones. The product height is not identical to total required installation clearance.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 57.
What features and values does FusionDC1000A have?
Select All that Apply.
Efficient
Simple
Reliable
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 59
“Quick Delivery & Simultaneous Deployment with Standard Standard product Civil work reference design Factory prefabrication Pretest before delivery Batch Delivery Simple installation 1 month Simultaneous arrival 1 day 59”
Technical Deep Dive
FusionDC1000A uses a prefabricated, plug-and-play design for simple deployment; integrates smart cooling and power systems for high energy efficiency and lower consumption; and provides reliable outdoor operation through its long-life enclosure and environmental protections.
Efficiency comes from integrated power conversion, containment and smart in-row cooling; simplicity comes from factory prefabrication and standardized interfaces; reliability comes from appropriate electrical redundancy and environmental protection. These three values are not separate unrelated slogans: they are design objectives that influence delivery time, energy use, maintainability and the resilience of the outdoor modular enclosure. Actual performance remains dependent on the installed configuration.
For this prefabricated 40-foot product, presales validation must distinguish physical cabinet arrangements, IT power density, UPS architecture, environmental limits, in-row cooling and the enclosure rating. A statement for one configured version must not be generalized to every deployment. Final designs also require suitable foundations, upstream connections, local safety compliance and commissioning checks.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Source reference: uploaded Huawei training material, PDF page 59.
Which of the following is included among the service configuration types offered by Meta CPQ?
Maintenance service
Implementation service
Supervision service
All of the above
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 95
“Configure services Set commerce Export Share Submit Configure Services Method 1: configure services through product models Method 2: configure services separately 1. Click Configure Service. 1. On the Configure page, click the product name to access the parameter configuration page. 2. Select desired services and add. 2. Click Service Parameter. Tips: Click here to learn more 3. Configure service parameters and save them. about the service 3. Set service parameters and save them. 26”
Technical Deep Dive
Meta CPQ supports maintenance service, implementation service, and supervision service as service configuration types; therefore, the option encompassing all three is correct.
The proposed service types include maintenance, implementation and supervision. These describe ongoing support, deployment execution and technical oversight respectively. Huawei's Meta CPQ slides directly confirm the ability to configure product-associated services or add standalone services, but they do not enumerate all three named categories. The all-of-the-above key is therefore intended but has a direct-source verification limitation.
In a production presales workflow, the configured BOQ must remain traceable to its customer and opportunity, and the product models, sales-part status, quantities and downstream commercial details must be validated before an order or quotation is finalized. A user-interface capability should not be mistaken for authorization to ignore an error or bypass role-based access restrictions.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Technical verification warning: The uploaded course confirms service configuration but not all three named service categories.
Source reference: uploaded Huawei training material, PDF page 95.
Which of the following UPSs does the FusionModule500 support?
Select All that Apply.
10kVA
3kVA
6kVA
15kVA
Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 53
“Detailed introduction of 4 basic configurations Power type 220/230/240V, 50/60Hz, 1Ph+N+PE 208V-2Ph+PE-60Hz Basic BC1L BC2L BC3L BC4L(Latin America) configuration Aisle type NO Cold and hot aisle containment UPS(KVA) 6 10 6 6 Cooling NO Integrated cooling Power input Single Single rPDU 1、2 (optional) 1、2 (optional) 2*40A/1P+2*40A/2P+1*32A/ IT output 5(4*40A+1*16A) 2*40A/1P+3*16A/1P 2P Smoke sensor, T & H sensor, Smoke sensor, T & H sensor, Standard intelligent lock, 10-inch PAD, intelligent lock, 10-inch PAD, Smoke sensor, T & H sensor, SMS/email alarm Configuration SMS/email alarm*, and local SMS/email alarm*, and local app O & M app O & M Fire extinguishing module, Fire extinguishing module, video surveillance, water Home A/C restart function, video surveillance, water video surveillance, water Optional leakage sensor, and mobile leakage sensor, door sensor, and mobile O & M”
Technical Deep Dive
The FusionModule500 integrates a single UPS whose available output capacity is either 6 kVA or 10 kVA (the two SKUs differ only in available rack space: the 6 kVA unit leaves up to 37U free and the 10 kVA unit up to 36U, with no battery pack installed). Huawei's current product specification lists 'Capacity: 6kVA/10kVA' under the power system section and does not offer a 3 kVA or a 15 kVA variant for this module, so only the 10 kVA and 6 kVA options are supported.
FusionModule500 uses 6 kVA and 10 kVA rack-mounted UPS capacities in its BC configurations. BC1L and BC3L use 6 kVA; BC2L uses 10 kVA; the specified Latin America BC4L uses 6 kVA. A 3 kVA or 15 kVA option is not listed. IT power limits still depend on cooling configuration and electrical design; nominal UPS kVA does not by itself define allowable cabinet heat load.
The FusionModule500 family contains cooled and noncooled configurations with different IT power limits. The selected UPS, room cooling conditions, battery runtime and enclosure arrangement must be checked together. A rating for a particular BC configuration must not be presented as the maximum or standard feature of every FusionModule500 installation.
Source reference: uploaded Huawei training material, PDF page 53.
BATCH 6 • QUESTIONS 76–90
TESTED 15 Nov 2026
Copyright © 2014-2026 CramTick. All Rights Reserved