Pre-Winter Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: cramtreat

NS0-521 Implementation Engineer - SAN ONTAP Exam Questions and Answers

Questions 4

What should an administrator use to protect an Oracle RAC Automatic Storage Management (ASM) instance to ensure automated restores?

Options:

A.

Availability groups

B.

NetApp SnapCenter plugin

C.

CLI snapshots and clones

D.

Consistency groups

Buy Now
Questions 5

A customer opens a support case for performance issues with an FC Oracle database after migrating from a NetApp AFF system to a NetApp All SAN Array (ASA) platform. Further investigation shows that the number of paths exceeds the recommendation for SAN deployment.

What are two ways to address this problem? (Choose two.)

Options:

A.

Use Selective LUN Mapping.

B.

Reconfigure the fabric switch zoning.

C.

Have the database team change their backup and recovery schedules for the database.

D.

Reconfigure the ALUA settings.

Buy Now
Questions 6

An administrator needs to configure Foreign LUN Import on a NetApp HA pair to migrate over FCP LUNs from a third-party array while serving other LUNs.

Which two actions are required to complete this task? (Choose two.)

Options:

A.

Reboot the third-party array to prepare for the LUN import.

B.

Convert all FC ports on each controller to an FC initiator port.

C.

Create zoning from the third-party array to the cluster.

D.

Convert a single FC port on each controller to an FC initiator port.

Buy Now
Questions 7

Which two NetApp features provide synchronous data replication between two sites for SAN workloads with automatic failover in case of a site disaster? (Choose two.)

Options:

A.

SnapMirror active sync

B.

SnapMirror SVM

C.

SnapMirror Synchronous

D.

MetroCluster IP

Buy Now
Questions 8

An administrator upgraded their NetApp ONTAP software from release 9.10.1 to 9.13.1 on a NetApp All SAN Array (ASA) cluster and is creating a new iSCSI SVM.

Which automatic feature can be used with iSCSI?

Options:

A.

LIF failover

B.

LUN mapping

C.

CHAP authentication

D.

igroup creation

Buy Now
Questions 9

An SVM is created for FCP traffic. LUNs must be created to share with ESXi hosts for datastores. Which two items must be configured after the LUN is created, for this to happen? (Choose two.)

Options:

A.

Create an igroup with the ESXi hosts' WWPNs.

B.

Create an igroup with the ESXi hosts' WWNNs.

C.

Configure CHAP authentication.

D.

Map the LUNs to the igroup.

Buy Now
Questions 10

A customer has a two-node NetApp AFF ASA cluster in an environment with a Cisco Fibre Channel SAN and Cisco UCS Servers. The customer wants to upgrade the UCS Server BIOS and the Cisco NX-OS system running on the switches.

Which NetApp resource should be consulted to check compatibility with the new versions?

Options:

A.

Interoperability Matrix Tool (IMT)

B.

BlueXP digital advisor

C.

Hardware Universe

D.

Active IQ Config Advisor

Buy Now
Questions 11

A four-node NetApp ONTAP SAN cluster has been deployed. After installation, the engineer wants to verify cabling.

Which NetApp tool should the engineer use?

Options:

A.

NetApp Host Utilities package

B.

Active IQ Config Advisor

C.

Interoperability Matrix Tool

D.

Hardware Universe

Buy Now
Questions 12

What configuration must be applied for NVMe/FC?

Options:

A.

Create multiple initiator zones and multiple target zones.

B.

Configure igroup and IQN mapping.

C.

Enable NPV on all fabric switches.

D.

Enable NPIV on all fabric switches.

Buy Now
Questions 13

A customer Is setting up a two-node cluster to serve (SCSI LUNs. How many interfaces should be created?

Options:

A.

One iSCSI LIF per node

B.

One ISCSI LIF per SVM

C.

Two iSCSI LIFs per node

D.

Two ISCSI LIFs per SVM

Buy Now
Questions 14

A customer asks for help cloning one database LUN from a SnapMlrror destination volume for testing the data with a new application.

What command should the administrator use to clone the LUN?

Options:

A.

volume fileclonecreate

B.

lun wovestart

C.

volumeclone create

D.

volumemove start

Buy Now
Questions 15

Which two steps must be taken first to restore a LUN from a SnapMirror Synchronous destination? (Choose two.)

Options:

A.

Resync the relationship.

B.

Release the relationship.

C.

Delete the relationship.

D.

Initialize the relationship.

Buy Now
Questions 16

An administrator has a NetApp AFF cluster supporting an application with twelve LUNs allocated across four volumes. There is a requirement to configure a Snapshot copy of all LUNs simultaneously as a single unit.

Which NetApp ONTAP command should be used to configure this requirement?

Options:

A.

lun igroup create

B.

network port ifgrp create

C.

volume conversion start

D.

vserver consistency-group create

Buy Now
Questions 17

Acustomer currently operates a legacy iSCSI storage environment that is connected to network switches with several Windows hosts. As part of an upcoming NetApp ONTAP software upgrade, an engineer needs to verify compatibility.

Which two NetApp tools would help the engineer assess the environment? (Choose two.)

Options:

A.

BlueXP classification

B.

Interoperability Matrix Tool

C.

Active IQ OneCollect

D.

Hardware Universe

Buy Now
Questions 18

A site survey has been conducted for an installation of a switchless HA pair with two NetApp DS224C shelves in the customer's already populated rack.

Which of the following two need to be verified to ensure a successful deployment? (Choose two.)

Options:

A.

Cluster switch location

B.

Rack units

C.

Power connections

D.

Crash cart location

Buy Now
Questions 19

An administrator configured an SVM with LUNs with two WWPNs per node. The administrator accidentally created a WWPN on node1that needs to move to node2. The SAN hosts use ALUA.

Based on this requirement, what must be taken offline to correct the situation?

Options:

A.

LIF

B.

LUN

C.

SVM

D.

Volume

Buy Now
Exam Code: NS0-521
Exam Name: Implementation Engineer - SAN ONTAP Exam
Last Update: Oct 14, 2024
Questions: 65
NS0-521 pdf

NS0-521 PDF

$28  $80
NS0-521 Engine

NS0-521 Testing Engine

$33.25  $95
NS0-521 PDF + Engine

NS0-521 PDF + Testing Engine

$45.5  $130