Weekend Sale Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: cramtreat

Note! Following 5V0-22.21 Exam is Retired now. Please select the alternative replacement for your Exam Certification. The new exam code is 5V0-22.23

5V0-22.21 VMware vSAN Specialist Questions and Answers

Questions 4

While preparing to update a vSAN cluster, an administrator finds that the firmware revision of the onboard storage controllers is no longer listed as supported in the Hardware Compatibility Guide, but new firmware is available.

Which action should the administrator take upon discovering this piece of information?

Options:

A.

Revert the cluster's on-disk format to the previous version.

B.

Replace all storage controller hardware.

C.

Configure additional external storage resources.

D.

Use vSphere Lifecycle Manager to update the controller firmware.

Buy Now
Questions 5

The Resyncing Objects view in the vCenter UI reports that some objects are currently resyncing.

Which two actions would cause this situation? (Choose two.)

Options:

A.

DRS is relocating VMs between vSAN nodes.

B.

HA Virtual Machine Monitoring forced a VM to reboot.

C.

A host failure occurs in the cluster.

D.

A change to the storage policy is applied to the objects.

E.

A VM snapshot is being deleted.

Buy Now
Questions 6

An administrator has deployed a new vSAN cluster that contains eight hosts and needs to configure a storage policy for the currently deployed database virtual machines. The requirements state that if two hosts in the vSAN cluster fail, all virtual machines are unaffected.

Which RAID configuration must the administrator use in this storage policy to achieve the best performance for the database virtual machines?

Options:

A.

RAID-0

B.

RAID-6

C.

RAID-5

D.

RAID-1

Buy Now
Questions 7

A vSAN administrator wants to upgrade a 4-node vSAN Cluster from version 7.0 to the latest version available. The vSAN administrator would like to complete the upgrade as a single task, including firmware and drivers for its hardware.

Which action must the administrator take in order to be able to perform the upgrade?

Options:

A.

Configure vSphere Update Manager (VUM).

B.

Migrate the workloads to allow the firmware to be upgraded.

C.

Install the new VMware LCM tool.

D.

Use vLCM images within Lifecycle Manager in vCenter.

Buy Now
Questions 8

A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources.

Which two strategies should the vSAN administrator use to achieve this goal? (Choose two.)

Options:

A.

RAID-5/FTT=1

B.

vSAN stretched cluster

C.

Specify fault domains

D.

RAID-6/FTT=2

E.

2-node configuration

Buy Now
Questions 9

Which two storage policy changes result in a component resync? (Choose two.)

Options:

A.

Changing object space reservation to 100

B.

Changing the failure tolerance method

C.

Disabling object checksum (from checksum enabled)

D.

Adding an IOPS Limit rule to a storage policy

E.

Enabling object checksum (from checksum disabled)

Buy Now
Questions 10

A vSAN administrator notices the VMware Skyline Health: Network Latency Check reports indicate three hosts are non-compliant.

Which action should the vSAN administrator take?

Options:

A.

Reboot the noncompliant hosts one at a time.

B.

Rerun the VMware Skyline Health: vSAN Cluster Partition report.

C.

Place the noncompliant hosts into an isolated network.

D.

Check VMKNICs, uplinks. VLANs. physical switches, and associated settings.

Buy Now
Questions 11

Which two storage policy types are used with the vSAN Data Persistence platform? (Choose two.)

Options:

A.

TKG extensions

B.

Harbor Registry

C.

Application name spaces

D.

Shared Nothing Architecture

E.

vSAN Direct Configuration

Buy Now
Questions 12

A vSAN administrator is looking forward to managing hypervisor, server drivers, and firmware all in one cluster image using vLCM. The vSAN administrator edits the desired Image and selects the desired ESXi version and Vendor Addon but is unable to add any firmware.

Why is there no firmware available to add to the image?

Options:

A.

All hosts in the cluster have the most current firmware installed already, and as a result, vLCM has no firmware to add to the image.

B.

The vCenter server version is older than 7.0, and as a result, vLCM does not support firmware addons.

C.

In order for firmware addons to be available, the administrator must first deploy the server vendor Hardware Support Manager

D.

The hosts listed in the cluster is managed by a vSphere Update Manager, so firmware updates are not possible.

Buy Now
Questions 13

A 100GB virtual disk object has this storage policy assigned to it:

  • Site disaster tolerance: None - standard cluster
  • Failures to Tolerate: 1 failure - RAID-1 (Mirroring)
  • Number of disk stripes per object: 3

What is the maximum amount of raw vSAN storage capacity consumed by this virtual disk?

Options:

A.

200GB

B.

100GB

C.

300GB

D.

600GB

Buy Now
Questions 14

A vSAN administrator is tasked to perform an upgrade of a vSAN cluster from 7.0 to 7.0 U2, including firmware and drivers for its hardware. The vSAN administrator already created an image using vSphere Lifecycle Manager (vLCM).

Prior to selecting Start Remediation, which step should be taken to upgrade the complete vSAN cluster as a single task?

Options:

A.

Select Remediate All through vLCM to upgrade all hosts in the cluster.

B.

Manually remediate one host at a time in the vSAN cluster.

C.

Place all hosts in the vSAN cluster into Maintenance Mode.

D.

Stage the upgrade of the vSAN cluster through vLCM.

Buy Now
Questions 15

In a 2-node vSAN cluster, one node has recovered from failure with FTT=1 and RAID-1 storage policy.

Refer to the exhibit:

What is the total VMDK storage consumed?

Options:

A.

150 GB

B.

100GB

C.

133GB

D.

200GB

Buy Now
Questions 16

An administrator is tasked with configuring vSAN Cloud Native Storage.

Which two requirements must be met for a successful configuration? (Choose two.)

Options:

A.

vSAN iSCSI service enabled

B.

Minimum of vSphere 6.7 Update 3 or later

C.

Tanzu Enterprise License required

D.

Minimum of vSphere 7.0 Update 2 or later

E.

Compatible version of Kubernetes

Buy Now
Questions 17

What does enabling vSAN operations reserve help ensure?

Options:

A.

Stores vSphere HA heartbeats

B.

Reconfigures data components

C.

Reserves space in case of single host failure

D.

Allocates capacity for vCLS

Buy Now
Questions 18

An Application Clustering Solution requires an in-guest attachable LUN which can be shared across two different VMs.

Which vSAN feature can meet this requirement?

Options:

A.

vSAN Data Persistence

B.

vSAN iSCSI Target Service

C.

vSAN HCI Mesh

D.

vSAN Datastore Sharing

Buy Now
Questions 19

A vSAN administrator has recently upgraded to vSAN 7.0 U1. The vSAN administrator wants to control the amount of Capacity Reserve to use the underutilized capacity of -140TB in the cluster of 12 vSAN ReadyNodes & 400TB storage for vSAN internal operations.

Which two options should be used to accomplish this goal? (Choose two.)

Options:

A.

Slack Rebuild Reserve

B.

Buffer Reserve

C.

Capacity Plan Reserve

D.

Host Rebuild Reserve

E.

Operations Reserve

Buy Now
Questions 20

An administrator needs an esxcli system command that will place a vSAN host into maintenance mode using the "Ensure Accessibility" option.

Which esxcli system command, if any, will work?

Options:

A.

There are no esxcli commands for MaintenanceMode.

B.

#esxcli system maintenanceMode set -enable true -m ensureObjectAccessibility.

C.

#esxcli system MaintenanceMode set -enable true -e ensureObjectAccessibility true.

D.

#esxcli system maintenanceMode set -enable false -m ensureObjectAccessibility.

Buy Now
Questions 21

Which two requirements should the vSAN administrator consider in order to accomplish this goal? (Choose two.)

Options:

A.

A leaf spine topology is required for core redundancy and reduced latency.

B.

NIC teaming must be implemented for the vSAN network vmkernel port.

C.

The configuration must meet the same latency and bandwidth requirement as local vSAN.

D.

Encryption must be disabled prior to configuring HCI mesh.

E.

Either Layer 2 and Layer 3 communications can be used.

Buy Now
Questions 22

An enterprise company is carrying out a planned yearly power test on specific platforms, and the infrastructure administrator has been asked to power down a vSAN 7.0 U1 cluster containing production virtual machines. The management workloads, such as the vCenter Server, are running on a different platform.

Which action should the vSAN administrator take to ensure it is safe to complete this task?

Options:

A.

Enter Maintenance Mode with Full data migration

B.

Review the vSAN proactive tests results from the vSphere client

C.

Review Data Migration Pre-Check results from the vSphere client

D.

Enter Maintenance Mode with ensure accessibility option

Buy Now
Exam Code: 5V0-22.21
Exam Name: VMware vSAN Specialist
Last Update: Feb 20, 2024
Questions: 149